RGB Output 1 — fine-tune the connected fixture in Lights
Live output
Master intensity
100%brightness
Recent scenes
Go to Scenes to save or manage looks
Setup and wiring
Unassigned devices & inputs
Hardware that isn't in a room yet — assign it so it appears in the correct space
Unassigned controller pins
Safe, inactive pins available for a new fitting or sensor
Curtains & blinds
Open / close / stop, or drag to a position
Dimmable fixtures
Single-channel white lights
Logical lighting architecture
Group fixtures into zones people understand.
A controller provides RGB Outputs. A fixture uses one output. A Zone groups one or more fixtures—normally inside a room—so they can share Looks, music and Automations.
Correct lighting workflow
Physical outputs and user-facing zones stay separate, while every connection remains traceable.
1OutputController reserves R, G and B pins2FixtureName the connected physical light3RoomPlace the fixture where it is installed4ZoneGroup one or more room fixtures5ExperienceApply Looks, music and Automations
◎
Lighting zones0Logical fixture groups
▥
Fixtures grouped0Connected RGB fixtures
+
Available outputs0Not connected to a room
⚡
Fixtures active0Controller-confirmed
Clear ownership
Output ≠ fixture ≠ zone
RGB Output is the controller resource and its physical R/G/B pins. Fixture is the connected lamp or an electrically linked group that always behaves together. Zone is a logical collection of independently connected fixtures. Sensors remain inputs and are never mixed into a lighting zone.
Logical grouping
Create lighting zone
Create the group first, then add or move fixtures into it without changing their physical wiring.
Space setup
Create room
Choose the kind of space, then connect the devices and sensors that belong there.
A suitable cover image is suggested. Equipment is never added until you select it.
Choose one
Keep the recommended image or upload your own at any time.
Optional
Upload your own room photo
Nothing is selected by default. Choose only equipment that is physically installed.
Anything already in another room is marked, so you can see where it lives.
Set up a controller
Which board do you have?
This takes about two minutes.
Controller point
Pin
Physical identity and live assignment
PHYSICAL PINH—GPIO
ASSIGNED PURPOSEAvailable controller pointNot connected to a room or fitting
LIVE STATEUnknownWaiting for controller
Where this pin is used
Follow the path from the controller to the exact room and fitting.
0 connections
iIdentify is temporary. It briefly pulses the selected output so the installer can find the physical fitting. Sensor points are read, never driven.
Changes are applied through the guided controller setup.
Room
⌄
———
Master Brightness
0%Brightness
—
Lights in this room
Named fittings, not controller zones
—
Target → design → preview → apply
Light Designer
One place for colour, effects and multi-step sequences
1 · Choose lightsSelect one fitting, several fittings, or the complete room
2 · Create the lookAn effect is one behaviour; multiple steps make a sequence
Or start with a presetChoose a ready-made design, then change any step
Sequence timelineDrag steps to reorder them, or adjust colour, effect and timingOpen timeline
3 · Preview and applyNo lights selected
Solid
Review the complete animation first. Apply sends the finished design only to the lights selected in step 1.
Music & Reactive Lights
Ready
1
Choose the lightsEach selected light uses the sequence already assigned to it.
2
Choose how sequences are routedKeep every light independent, or temporarily use one reference sequence.
♪
Now playingChoose music to beginLocal music · private on this deviceChoose a lighting sequence below
0:000:00
Category Setup
Recommended items for this room type
Configured controller items
Assign existing outputs or sensors; use Add light to create a new fitting
Room Layout
Installation positions
Room Intelligence
Local recommendations
Operational controls
Pumps, heating, valves, access, airflow, coverings and appliances
Curtains, blinds & covers
Interlocked open / close equipment
Planned controls
Recommended for this type of space
ϟ
Energy & Running Cost
Live load and daily operating estimate
Estimated
¤
◷
⌁
Sensor History
Readings captured during this session
Monitoring coverage
Configured readings and recommended measurement points
Safety status & diagnostics
Alerts & activity
Safety coverage
Required and recommended monitoring points for this space
Room Experience
Owner / administrator
Hide functions this room does not need. Choices follow the room to every signed-in device.
Ambience Scenes
What this scene captures
Live readout — set it up on Studio/Rooms first
Save this look
PreviewCurrent output
Saved scenes
Showing all categories
Party Experience
Run a coordinated colour experience on the RGB fixtures in the selected Control Group.
Music Sync
Live microphone → LED reaction
Mic off
Bass
Mid
Treble
🖥This tab / browser audio
🎤Microphone
Audio is analysed in this page and never recorded, stored or sent anywhere.
Selected group fixtures
Control Group target
YouTube music
Play a track here, then let the lights follow it
No track loaded
Saved tracks
Stored on this computer
When prompted, choose This tab and enable Share tab audio.
Guest access
Show this at the door
Share an event invitation.
When this → do that
One clear rule connects a trigger to an action
Control station runtime
1TriggerA time or a verified controller input2ActionStart or stop a preset, scene, or sequence3PrioritySafety wins, then High, then Normal!Current executionThis screen must remain open and connected; gateway-resident scheduling is the production target
Time rules
Sensor rules
Saved sequences
Chained looks that play back automatically
New sequence
Each step drives the assigned controller outputs through the active gateway
No steps yet — add one above.
Idle
RGB Output 1 · Effects engine
Advanced live tuning for the fixture connected to this controller output
Wiring: RGB Output 1's R/G/B channels are mapped onto header pins H30/H5/H27 on every connect (PINMAP). Common-cathode: tie the LED common pin to GND and use a 220–330 Ω resistor per channel.
Colour
#5B8CFF
Intensity
Master level for this colour
100%
Brightness is applied on the controller, so one colour can swell and dim smoothly without the browser having to keep up.
Create a rule or choose an existing one to see its complete control path.
Preset Library
Real saved presets
Recent Activity
Controller-session results
Rule Priority
Higher priority wins a conflict
Reusable presets
Choose the result once. Reuse it anywhere.
A preset combines selected fittings, light movement, and optional music response. A rule can then start or stop it automatically.
10Presets20Available fittings30Active rules
1Choose a moodParty, relax, focus…›2Select fittingsTick rooms or individual lights›3Add optionsMusic and timing are optional
Advanced preset toolsFixture groups, exact sequences and music response
Setup warnings and conflicts
No looks yet
A preset combines fixtures, light behaviour, optional music and timing.
Advanced fixture membership
Choose which fittings participate together.
A fixture remains owned by its room. A Fixture Group only references it, so the same light can participate in Party Area, Ground Floor and Welcome Path.
Synchronized target
Which fixtures should follow this beat?
The analyser produces one shared beat clock. Commands are distributed to the selected group's real RGB outputs through the active controller transport.
Automation activity
Real events from this control-station session; no fabricated history
Reusable cross-room selection
Create fixture group
Select rooms or individual fixtures. Nothing is rewired and fixture ownership never changes.
One source of truth
Rooms own fixtures. Groups reference them. Presets and rules use the group. Controller outputs and physical pins remain unchanged.
Three simple steps
Create a preset
Choose the result, tick the fittings and save. A rule can start it later.
1Mood2Fittings3Review
What atmosphere do you want?We apply suitable colours and movement automatically.
Where should it happen?Select a complete room or individual fittings.
Ready to saveMusic and scheduling are optional. The normal choice is already selected.
Customize light movement
Choose at least one fitting to continue.
AURA setup
Set up your controller
Choose a system. AURA prepares the rest.
Template-first setup
AURA controller platform
One product contract. Any validated controller.
Controllers keep one permanent identity. A versioned hardware profile defines what the board can safely do, transport adapters define how it is reached, and firmware compatibility is checked before any output is claimed.
AURA product factory
Choose the product role you are installing
The product role defines its responsibility. The hardware package and live firmware define which physical resources can actually be assigned.
AURA controller catalog
01IdentityOne permanent ID per physical controller02Hardware profileVersioned pins, capabilities and safety limits03Transport adaptersUSB today; secure IP and field buses through adapters04Firmware familyCompatibility checked before commissioning
Industrial commissioning workflow
Discovery never energises outputs. A controller becomes operational only after every gate passes.
Loading contract…
1DiscoverRead identity2ValidateMatch profile and firmware3BindAssign equipment resources4VerifyRun safe channel tests5CommissionRelease to rooms and automations
Add controller · Wi-Fi commissioning
Connect AURA to this property
Temporary hotspot → local Wi-Fi → secure controller discovery
1Join controller2Choose network3Return to property Wi-Fi4Verify
1Join the temporary controller networkOn this phone or tablet, open Wi-Fi settings and connect to the AURA network printed on the controller label.
AURA hotspotAURA-171084Setup key: use the unique key printed on this controller
If the phone reports “No internet”, choose Stay connected. This network is only the secure setup bridge.
2Open the controller setup screenThe controller scans nearby networks itself. Select the property Wi-Fi and enter its password there.
This button works only while the phone is connected to the AURA hotspot.
3Return to the local Wi-FiAfter the controller reports success, reconnect this phone to the same property network selected during setup.
The controller keeps its permanent identity. A changing router IP never creates a second controller.
4Find and verify the controllerAURA discovers the controller, validates its identity and certificate, then enables normal room controls.
Ready to verify.
⏱
Session time00:00
⌁
Commands sent0
✺
Top effect—
▤
Scenes saved0
Effect usage this session
Real command counts for RGB Output 1's connected fixture
Brightness trend
Real local telemetry — no cloud, nothing fabricated. There's no power meter on this board, so this tracks usage, not kWh.
Gate & access
Main Gate
Operate the gate, control its light and verify every movement from physical feedback.
Controller unavailableSetup required
Physical position
Gate status
UNKNOWN
Position feedback has not been commissioned.
?UNKNOWN
Independent camera library
Gate cameras
View and manage multiple entrance cameras. Camera credentials remain in the local media gateway, never in this browser.
Camera metadata
Add camera
Not tested
Operational audit
Gate history
Commands, physical confirmations, lighting changes and safety blocks.
Installer commissioning
Configure the gate from one guided page
Assign real controller points, prove the compulsory safety inputs, configure automatic gate lighting and connect a browser-safe camera gateway.
1
Gate operator
Select how the certified gate controller accepts commands.
2
Position & compulsory safety
Gate state is valid only when physical contacts confirm it. Safety remains hard-wired to the gate operator.
3
Gate light automation
Use a real output plus darkness and presence inputs. Sensor failure never creates a false “safe” status.
4
Access trigger
Use an authorised dry-contact output from an access controller. OSDP readers require a supported access adapter; raw credentials are not processed as a generic GPIO.
5
Camera handoff
Cameras are independent network devices and are managed separately from controller pins. Add as many gate cameras as the site requires in the Cameras workspace.
Smart pool
Pool control & water health
See the important readings, control equipment and create the perfect poolside ambience.
Awaiting commissioned telemetry
DMX512 universe
Output disabled
DMX output is disabled in this firmware profile because H15 and H18 are wired to the DMX UART peripheral, not free GPIO — they can't also be used for zone colour pins.
255
Channel monitor
Channels 1–128 · click to set a level
Hardware & I/O
▦
Controller
Loading hardware profile…
Saved profile
Guided connection
What are you connecting?
Choose the equipment first. AURA validates its interface and recommends only compatible controller points.
Saved controller profile
Controller brain
Every circuit, fitting and physical pin
The single answer to “which pin is that?”
Controller verification
Firmware & connection
Refreshes live information from the selected controller. Saved browser data is never presented as a live result.
⌁
Control endpointWhere this controller is reached
Device URL
Not reported
Transport
Offline
Controller UID
Not reported
{ }
Communication contractSchema understood by application and firmware
Processor healthESP32 network processor and STM32 field I/O
ESP32-C6
Not verified
STM32G0B1RE link
Not verified
Fail-safe
Not verified
Signed update workflow
Install an approved firmware image
Use an HTTPS URL generated by the AURA release service. The controller downloads into the inactive partition, restarts, validates the I/O processor, and rolls back automatically when validation fails.
No update runningRefresh the controller before starting an update.
Controller registry
One saved configuration per physical controller UID
No identified controllers yet.
Controller configuration
The real backend — assign which physical pin drives every zone and relay. Edit here to onboard a differently-wired controller without touching code.
USB not readNot connected
Connect a controller to read its self-description.
Templates claim all required pins together. Unsupported electrical interfaces are blocked instead of creating a device that cannot work.
Review pin assignmentsAdvanced mapping, safety validation and controller applyOpen editor
Assign only inputs the application should read. Every unassigned GPIO stays inactive and is omitted from board readings.
Each motor needs two relay pins — one per direction. Position is estimated from travel time; these motors send no feedback.
Single PWM channel per fixture. Requires firmware with PINPWM, which the AURA controllers support.
Firmware-controlled GPIO pins
Only ports implemented by the connected AURA controller firmware
Pins reserved by the current controller configuration are locked below — edit assignments above under Controller configuration.
RGB diagnostic is idle. The test never energises the Gate or Pool-pump relay pins.
Household members